Skip to main content
BuyerBuy & source

Moving a Used Pressure Vessel Between Provinces: CRN, ABSA and TSASK Explained

What a CRN covers, and what ABSA, TSASK, Technical Safety BC and Manitoba ITS expect when you move a used vessel between Western Canadian provinces.

By Redeploy HQ6 minute read · 7 topicsUpdated Nov 15, 2026
In this guide

Buyer checklist

  1. 01

    Overview

    A used separator, scrubber, coalescer or other pressure vessel that is legal to operate in one Western Canadian province is not automatically accepted in the next. Design registration is done by each provincial or territorial authority. The Canadian Registration Number (CRN) identifies a registered design; you still have to satisfy the authority in the province where the vessel will be installed or operated. This guide explains what to collect from the seller and where to go next. It is not a registration application and it does not replace advice from the regulator or a qualified pressure-equipment professional.

    Browse used pressure vessels, including vessels in Alberta. The same issues apply to used separators and to vessels that travel with used compressor packages.

  2. 02

    What a CRN is — and what it is not

    A CRN is issued when a boiler or pressure-vessel design is accepted for registration. In British Columbia, Technical Safety BC states that boilers and pressure equipment require design registration in accordance with CSA B51, *Boiler, Pressure Vessel, and Pressure Piping Code*. Manitoba’s Inspection and Technical Services (ITS) similarly registers acceptable designs and denotes acceptance with a CRN.

    A CRN tells you that a design was registered in one or more jurisdictions. It is not, by itself:

    The number is usually on the nameplate, often with a letter or suffix that indicates the registering jurisdictions. Photograph the nameplate. Do not alter it. Saskatchewan’s used-vessel requirements state that the owner or operator is not permitted to alter the nameplate, and that unauthorized alterations may result in the vessel being condemned for pressure service.

    If the vessel has no nameplate, an unreadable nameplate, or no data report, treat registration and acceptance as an open question before you buy, not as a problem to solve after the tank is on a truck.

    • Proof that this particular used vessel is still fit for service
    • Permission to install or operate the vessel in a province that has not registered the design, or has not accepted the used vessel
    • A substitute for the manufacturer’s data report, nameplate, and current inspection condition
  3. 03

    Alberta: ABSA

    The pressure equipment safety authority in Alberta is ABSA. ABSA’s design-registration FAQs state that the designs of all boilers and pressure vessels to be operated in Alberta must be registered in Alberta. A registration or stamp from another province, or an ASME stamp with National Board registration, does not replace Alberta design registration.

    For used equipment coming into Alberta without an Alberta CRN, ABSA’s PESR user guide (AB-516) states that a condition report is required, such as a recent ultrasonic thickness measurement or, where appropriate, a good visual inspection. Importing used pressure piping into Alberta is discouraged in that guide because of the difficulty of verifying materials, design and workmanship.

    If you are buying a vessel that will be installed in Alberta, ask the seller for the Alberta CRN if one exists, the manufacturer’s data report, drawings and calculations if they are available, nameplate photographs, and any recent UT or inspection report. Then confirm the current acceptance path with ABSA or with a registrant who does this work regularly. Do not assume that a Saskatchewan or British Columbia CRN is enough.

  4. 04

    Saskatchewan: TSASK

    The Technical Safety Authority of Saskatchewan (TSASK) is the authority for boilers and pressure vessels in Saskatchewan. TSASK’s requirements for acceptance of used pressure vessels state that a used vessel must possess a Saskatchewan CRN and must have been designed and manufactured in accordance with ASME Section VIII, Division 1 and CSA B51, subject to the published conditions. If the vessel does not have a Saskatchewan CRN, detailed design drawings, calculations and a copy of the manufacturer’s data report must be submitted for review. If a Saskatchewan CRN is then issued, the local inspector restamps the nameplate.

    TSASK also notes an alternative to CRN registration, under which an owner may register a manufacturer’s data report in lieu of obtaining a Saskatchewan CRN when the regulatory conditions are met. That alternative is an official option, not an informal workaround; confirm it with TSASK before you rely on it.

    If the vessel already has a Saskatchewan CRN, acceptance is handled by the local inspector. TSASK requires a copy of the manufacturer’s data report, and final acceptance is based on a physical inspection. Further non-destructive examination or a hydrostatic test may be ordered if the condition is in question. Previous inspection reports from other provinces and recent NDE results may help, but excessive corrosion or other defects may still lead to rejection.

    A CRN from another province is treated as a reciprocal registration in Saskatchewan; TSASK states that you still need to register it there, though the design review is typically shorter than a first registration. National (multi-jurisdiction) CRN registration is a separate process, used when a design is being registered in several jurisdictions at once, and is not a substitute for checking the used-vessel path for a specific move.

  5. 05

    British Columbia and Manitoba

    In British Columbia, Technical Safety BC requires design registration for boilers and pressure equipment under CSA B51. Applications go through its Design Registration Portal. TSBC publishes a separate document checklist for used or re-rated boilers, pressure vessels and heat exchangers, which is the starting point for a used vessel that will be installed in B.C.

    In Manitoba, Inspection and Technical Services reviews designs for compliance with the Act, regulations and applicable codes, and issues a CRN for accepted registrations. ITS states that owners, users, agents, manufacturers, contractors and installers are responsible for registering equipment designs before manufacturing, fabrication, installation or importing from another jurisdiction or country. Reciprocal and revised designs are part of that process. Submissions are made electronically.

    In every province, the registration of a design does not relieve the people who design, construct, install, alter or repair the equipment of their responsibilities. A used vessel can have an acceptable design and still be rejected on condition.

  6. 06

    What to request from the seller

    Before you commit to a used vessel, separator or compressor-package vessel, ask for:

    Keep each record tied to the serial number on the nameplate. A data report for a different vessel is not useful. For a general document approach, see Documents for buying used oilfield equipment in Canada.

    Moving the vessel is a separate problem from registering it. Confirm shipping dimensions, weight, lifting lugs or saddles, and oversize or overweight permits with the carrier. A vessel can be transported under a permit and still be unusable in the destination province until the authority accepts it.

    • Photographs of the nameplate, including the CRN, manufacturer, serial number, year, MAWP, and temperature limits
    • The manufacturer’s data report
    • Drawings and design calculations, if they exist
    • Inspection, repair and alteration records, including any UT or other NDE
    • Previous service (sweet or sour, product, design pressure and temperature) and known damage or local thin areas
    • The current location and how the vessel will be loaded
  7. 07

    Buying on Redeploy HQ

    Redeploy HQ lists used and surplus pressure vessels, separators and compressor packages from Western Canadian sellers. Use the listing to compare diameter, length, pressure, CRN information and location, then confirm the registration path for the province of use. Start with pressure vessels or Alberta pressure vessels, and review separators and compressor packages when the vessel is part of a package.

Common questions

If a vessel already has a CRN, can I install it in another province?

Not automatically. Each province registers designs, and a used vessel also has to be accepted on condition. Alberta requires Alberta registration for vessels operated in Alberta. Saskatchewan treats an out-of-province CRN as a reciprocal registration and still requires that step, or an accepted alternative. Confirm the destination authority before you buy.

What is the difference between a CRN and a manufacturer’s data report?

The data report is the manufacturer’s certified record of how the vessel was built. The CRN is the registration number assigned when a jurisdiction accepts the design. You typically need both, plus evidence of the vessel’s current condition.

Can I restamp a nameplate myself after a new CRN is issued?

No. Follow the authority’s process. In Saskatchewan, TSASK states that the local inspector restamps the nameplate if a Saskatchewan CRN is issued, and that the owner or operator must not alter the nameplate.

Do compressor-package vessels and separators follow the same rules?

The pressure vessels on a package — scrubbers, separators, coalescers and similar — are still pressure vessels. Confirm the CRN and data report for each registered vessel on the skid, not only for the compressor frame.

What if the nameplate is missing or unreadable?

Treat that as a serious obstacle to acceptance. Ask whether a data report and drawings exist and speak with the destination authority or a qualified registrant before you purchase. Buying a vessel you cannot identify is a common way to end up with equipment that cannot be put back into pressure service.

Sources and further reading

Check the current guidance for the equipment, location and work involved.