Skip to main content
BuyerBuy & source

Pump jack sizes: API 11E

How to read an API 11E pumping unit designation such as C-228D-213-86, and what torque, structure and stroke figures mean when you buy a used pump jack.

By Redeploy HQ5 minute read · 7 topicsUpdated Nov 15, 2026
In this guide

Buyer checklist

  1. 01

    Overview

    Used pump jacks, also written pumpjacks or pumping units, are usually described with an API Spec 11E size designation such as C-228D-213-86. That string is the most useful comparison on a listing if you know how to read it. This guide walks through each part of the designation, shows what those numbers mean on a typical conventional unit, and lists what to inspect before you buy. It explains the designation as it appears on manufacturer catalogues and nameplates; API Spec 11E itself is a copyrighted standard and should be consulted directly for the official requirements.

    Browse used pump jacks for sale, including pump jacks in Saskatchewan and Alberta. For heavy-oil wells that use a different lift method, see used progressive cavity pumps.

  2. 02

    The four parts of an API 11E designation

    A typical conventional-unit designation has four parts. Taking C-228D-213-86 as the example:

    Manufacturer catalogues use the same pattern on other sizes. A conventional unit listed as C-456D-305-168, for example, is a conventional geometry with a 456,000 in-lb double-reduction reducer, a 30,500 lb structural rating and a 168 in maximum stroke. Always read the nameplate or the seller’s designation rather than inferring size from a photograph.

    Hyphens and spaces vary in listings (C-228D-213-86, C228D-213-86, C 228D 213 86). The meaning does not change if the four parts are the same.

    PartIn the exampleWhat it tells you
    Unit type (geometry and balance)CConventional, crank-balanced unit
    Peak torque and reducer type228DGear reducer with a peak torque rating of 228,000 in-lb, double reduction
    Structural (polished rod) rating213Structure rated for 21,300 lb of polished rod load
    Maximum stroke length86Longest stroke the unit can be set to, in inches
  3. 03

    Unit type letters you will see

    The first letter describes the geometry and how the unit is balanced. Common letters in manufacturer catalogues are:

    Other letters appear on some lines (beam-balanced or specialized geometries). If the prefix is not C, A or M, ask the seller which geometry it is and for the manufacturer’s model sheet. Do not assume two units with the same torque and stroke are interchangeable if the geometry is different; the rod-load profile and the site layout are not the same.

    • C — conventional, crank-balanced beam unit. This is the most common used unit in Western Canada.
    • A — air-balanced unit.
    • M — Mark II or front-mounted geometry, depending on the manufacturer’s usage.
  4. 04

    Torque, structure and stroke

    Peak torque is the gear reducer’s rating, in thousands of inch-pounds. In C-228D-213-86, “228” is 228,000 in-lb. This has to suit the well’s torque demand, not only the structure rating. A unit can have plenty of structure capacity and still be under-torqued for the well, or the reverse.

    D in these designations is the reducer type, commonly a double-reduction gear reducer. If a listing omits the letter, ask whether the reducer is double reduction and what the exact model is.

    Structural rating is the polished rod capacity, in hundreds of pounds. “213” is 21,300 lb. Manufacturer data for a C-228D-213-86 conventional unit lists a rated polished rod capacity of 21,300 lbf and a rated torque of 228,000 lbf·in, which matches the designation.

    Maximum stroke is in inches. “86” means the longest available stroke is 86 in. Units are usually settable to shorter strokes as well. Catalogue data for a C-228D-213-86, for example, shows shorter stroke options in addition to the 86 in designation. The stroke you need for the well may be less than the maximum; what you cannot do is run a longer stroke than the unit provides.

    Two units with the same reducer (both 228D, for example) may have different structure ratings and strokes. C-228D-213-86 and C-228D-246-86 share torque and maximum stroke but not structure rating. Compare all four parts, not only the 228D.

  5. 05

    What to confirm on a used pump jack

    Ask the seller for:

    Inspect for cracked or bent structural members, worn pins, a leaking or noisy reducer, a weak or inoperative brake, damaged wireline (bridle), and missing weights or hardware. Ask when the unit last ran and why it was taken off the well. Confirm that the designation on the nameplate matches the listing.

    Transport of a pumping unit is a planned lift. Confirm whether the unit will be sold standing or down, who is responsible for ramping and loading, and the dimensions and weight for the move. An assembled unit can be a high, wide load; a disassembled unit is several lifts.

    • The exact designation, manufacturer and serial number, with a nameplate photo
    • The current stroke setting and the available stroke holes or positions
    • Prime mover type (electric motor or engine), horsepower, and whether it is included
    • Gear-reducer condition: oil condition, leaks, noise history, and any rebuild records
    • Structure condition: walking beam, Samson post, equalizer, pitman arms, wrist pins, bridle and carrier bar, brake, and wellhead or base arrangement
    • Whether the sale includes the base, weights, belts, sheave, motor or engine, and bridle
    • Location, and whether the unit is standing, stacked or already down for transport
  6. 06

    Pump jack or PCP?

    Searchers write both “pump jack” and “pumpjack.” On Redeploy HQ the category slug is `pump-jack`. A pump jack is a beam pumping unit that drives a sucker-rod pump. A progressive cavity pump (PCP) with a drivehead is a different lift system, common in heavy oil around Lloydminster. If you are comparing lift methods rather than unit sizes, look at both the pump jack and progressive cavity pump categories.

  7. 07

    Buying on Redeploy HQ

    Redeploy HQ lists used and surplus pumping units from Western Canadian sellers, including inventory in Saskatchewan and Alberta. Compare the full API designation, what is included with the sale, and the seller’s location. Start with used pump jacks, then narrow to Saskatchewan or Alberta when you are buying in a specific province.

Common questions

What does C-228D-213-86 mean?

It is a conventional (C) pumping unit with a double-reduction (D) gear reducer rated at 228,000 in-lb peak torque, a 21,300 lb polished rod (structural) rating, and an 86 in maximum stroke. Confirm the nameplate on the unit you are buying.

Is the stroke always 86 inches on that unit?

No. 86 in is the maximum stroke in the designation. The unit can usually be set to shorter strokes. Ask which stroke it is currently set to and which positions are available.

Do I match a used pump jack only on torque?

No. Compare geometry, torque, structure rating and stroke, plus the prime mover and the condition of the reducer and structure. A well that needs a long stroke and a high rod load will not be served by matching torque alone.

Are “pump jack,” “pumpjack” and “pumping unit” the same equipment?

In used-equipment listings they usually are. “Pumping unit” is the term used in API Spec 11E. “Pump jack” and “pumpjack” are the common search terms. A PCP drivehead is different equipment.

What records should come with a used pumping unit?

Ask for the nameplate designation, serial number, any reducer rebuild or maintenance records, and a list of included components. There is often no full history on a used unit, so a visual inspection and a clear list of what is included matter as much as the paperwork.

Sources and further reading

Check the current guidance for the equipment, location and work involved.